ANSI AIHAZ 9.1-2006 粗糙表面油罐操作空气传播污染物的控制和通风
作者:标准资料网 时间:2024-05-15 16:26:52 浏览:8507
来源:标准资料网
【英文标准名称】:VentilationandControlofAirborneContaminantsDuringOpen-SurfaceTankOperations
【原文标准名称】:粗糙表面油罐操作空气传播污染物的控制和通风
【标准号】:ANSIAIHAZ9.1-2006
【标准状态】:现行
【国别】:美国
【发布日期】:2006
【实施或试行日期】:
【发布单位】:美国国家标准学会(US-ANSI)
【起草单位】:ANSI
【标准类型】:()
【标准水平】:()
【中文主题词】:空气;污染物;控制;设计;防火;最低要求;个人保健;人员;保护(装置);公共卫生;表面;油罐操作;通风控制;通风系统
【英文主题词】:Air;Contaminants;Control;Controlling;Design;Fireprotection;Minimumrequirements;Personalhealth;Personnel;Protection;Publichealth;Surfaces;Tankoperation;Ventilationcontrol;Ventilationsystems
【摘要】:Establishesminimumcontrolrequirementsandventilationsystemdesigncriteriaforcontrollingandremovingaircontaminantstoprotectthehealthofpersonnelengagedinopen-surfacetankoperations.Itisnotintendedtocoverfireprotection.
【中国标准分类号】:Z50
【国际标准分类号】:13_040_01;13_300
【页数】:
【正文语种】:英语
基本信息
标准名称: | 多道心理测试系统通用技术规范 |
英文名称: | General specification for polygraph system |
中标分类: |
综合 >>
社会公共安全 >>
犯罪鉴定技术 |
ICS分类: |
计量学和测量、物理现象 >>
计量学和测量综合
|
发布部门: | 中华人民共和国公安部 |
发布日期: | 2005-06-10 |
实施日期: | 2005-08-01 |
首发日期: | 1900-01-01 |
作废日期: | 1900-01-01 |
提出单位: | 公安部刑事侦查局 |
归口单位: | 公安部特种警用装备标准化技术委员会 |
起草单位: | 公安部刑事侦查局刑事科学技术工作处、中国科学院自动化研究所等 |
起草人: | 王艳军、张吉华、宋立波、朱翔、陈云林等 |
出版社: | 中国标准出版社 |
出版日期: | 2005-08-01 |
页数: | 8页 |
书号: | 155066.2-16379 |
适用范围
本标准规定了多道心理测试系统的技术要求、试验方法、检验规则、标志、包装、运输和贮存等要求。
本标准适用于多道心理测试系统的设计、生产、检验和贸易。
前言
没有内容
目录
没有内容
引用标准
没有内容
所属分类: 综合 社会公共安全 犯罪鉴定技术 计量学和测量 物理现象 计量学和测量综合
【英文标准名称】:StandardTestMethodforConductingCyclicPotentiodynamicPolarizationMeasurementstoDeterminetheCorrosionSusceptibilityofSmallImplantDevices
【原文标准名称】:进行循环动电位极化测量以测定小型植入装置的腐蚀敏感性的标准试验方法
【标准号】:ASTMF2129-2008
【标准状态】:现行
【国别】:美国
【发布日期】:2008
【实施或试行日期】:
【发布单位】:美国材料与试验协会(US-ASTM)
【起草单位】:F04.15
【标准类型】:(TestMethod)
【标准水平】:()
【中文主题词】:
【英文主题词】:corrosion;cyclicpolarization;medicaldevicetesting;pittingpotential;protectionpotential;restpotential;Corrosion--surgicalimplants;Cyclicpotentiodynamicpolarizationmeasurement
【摘要】:Corrosionofimplantablemedicaldevicescanhavedeleteriouseffectsonthedeviceperformanceormayresultinthereleaseofcorrosionproductswithharmfulbiologicalconsequences;therefore,itisimportanttodeterminethegeneralcorrosionbehavioraswellasthesusceptibilityofthedevicestolocalizedcorrosion.Theformingandfinishingstepsusedtocreateanimplantabledevicemayhavesignificanteffectsonthecorrosionresistanceofthematerialoutofwhichthedeviceisfabricated.Duringtheselectionprocessofamaterialforuseasanimplantabledevice,testingthecorrosionresistanceofthematerialisanessentialstep;however,itdoesnotnecessarilyprovidecriticaldataregardingdeviceperformance.Toaccommodatethewidevarietyofdeviceshapesandsizesencountered,avarietyofholdingdevicescanbeused.Notethatthemethodisintentionallydesignedtoreachconditionsthataresufficientlyseveretocausebreakdownanddeteriorationofthemedicaldevicesandthattheseconditionsmaynotbenecessarilyencounteredinvivo.Theresultsofthiscorrosiontestconductedinartificialphysiologicalelectrolytescanprovideusefuldataforcomparisonofdifferentdevicematerials,designs,ormanufacturingprocesses.However,notethatthistestmethoddoesnottakeintoaccounttheeffectsofcells,proteins,andsoforthonthecorrosionbehaviorinvivo.1.1Thistestmethodassessesthecorrosionsusceptibilityofsmall,metallic,implantmedicaldevices,orcomponentsthereof,usingcyclic(forwardandreverse)potentiodynamicpolarization.Examplesofdevicetypesthatmaybeevaluatedbythistestmethodinclude,butarenotlimitedto,vascularstents,ureteralstents(SpecificationF1828),filters,supportsegmentsofendovasculargrafts,cardiacoccluders,aneurysmorligationclips,staples,andsoforth.1.2Thistestmethodisusedtoassessadeviceinitsfinalformandfinish,asitwouldbeimplanted.Thesesmalldevicesshouldbetestedintheirentirety.Theupperlimitondevicesizeisdictatedbytheelectricalcurrentdeliverycapabilityofthetestapparatus(seeSection6).Itisassumedthattestmethods,suchasReferenceTestMethodG5andTestMethodG61havebeenusedformaterialscreening.1.3Becauseofthevarietyofconfigurationsandsizesofimplants,thistestmethodprovidesavarietyofspecimenholderconfigurations.1.4Thistestmethodisintendedforuseonimplantabledevicesmadefrommetalswitharelativelyhighresistancetocorrosion.1.5ThevaluesstatedinSIunitsaretoberegardedasstandard.Nootherunitsofmeasurementareincludedinthisstandard.1.6Thisstandarddoesnotpurporttoaddressallofthesafetyconcerns,ifany,associatedwithitsuse.Itistheresponsibilityoftheuserofthisstandardtoestablishappropriatesafetyandhealthpracticesanddeterminetheapplicabilityofregulatorylimitationspriortouse.^REFERENCE:ASTMStandards:D1193SpecificationforReagentWaterE177PracticeforUseoftheTermsPrecisionandBiasinASTMTestMethodsE691PracticeforConductinganInterlaboratoryStudytoDeterminethePrecisionofaTestMethodF1828SpecificationforUreteralSten......
【中国标准分类号】:C45
【国际标准分类号】:11_040_40
【页数】:9P.;A4
【正文语种】:英语